Is this a full size pickup (C/K) or a small (S/T)? If full size- has it ever been wrecked-in front end to where condenser has been replaced? have seen numerous cases where the plumbing is reversed at the condenser- GM in their infinite wisdom has the same threads on condenser inlet as outlet- and body shop technicians are not necessarily a/c technicians- and have plumbed them backwards--